HOLIP变频器与 LG PLC的通讯
// 备注:变频器参数设定:变频器地址:001;波特率:9600;通讯资料方式:8位元无校验ASCII码
// Serial A CD160 = 1;CD161 = 1;CD162 = 0; CD033=2; CD034=2
// Serial C C109=1; C110=1; C111=0; C012=2; C013=2
MOV 05000 D0550 |
装载频率50Hz |
DIV D0550 00256 D0000 |
MOV 00000 D0050 |
MOV 00001 D0052 |
分离数据高低位 |
ASC D0550 D0060 00002 |
ASC D0052 D0064 00002 |
将频率数据转换为ASCII码 |
ADD h0006 D0000 D0100 |
ADD D0001 D0100 D0100 |
计算LRC校验 |
MOV 00256 D0110 |
SUB D0110 D0100 D0100 |
ASC D0100 D0110 00002 |
F0010 |
0 |
组织频率数据 |
F0010 |
70 |
WAND D0060 h00FF D0302 |
WOR D0300 h0030 D0300 |
WAND D0060 hFF00 D0300 |
WAND D0064 hFF00 D0304 |
WAND D0064 h00FF D0306 |
WOR D0304 D0302 D0308 |
WAND D0110 hFF00 D0310 |
WAND D0110 hFF00 D0312 |
WOR D0310 D0306 D0314 |
MOV h0D00 D0316 |
WOR D0316 D0312 D0318 |
201 |
246 |
291 |
146 |
MOV h0303A D0500 |
设定串口频率 |
MOV h03032 D0502
|
MOV h03033 D0503
|
P0000 |
启动变频器 |
P0001 |
MOV h03031 D0501
|
MOV D0308 D0505 |
MOV D0314 D0506 |
MOV D0300 D0504 |
MOV D0318 D0507 |
MOV h000A D0508 |
DSND 00001 00017 D0500 M000 |
MOV h303A D0600 |
MOV h3033 D0602
|
MOV h3031 D0603
|
MOV h3031 D0601
|
MOV h0D41 D0605 |
MOV h000A D0606 |
MOV h4631 D0604 |
DSND 00001 00013 D0600 M000 |
停止变频器 |
P0002 |
MOV h303A D0650 |
MOV h3033 D0652
|
MOV h3031 D0653
|
MOV h3030 D0651
|
MOV h0D34 D0655 |
MOV h000A D0656 |
MOV h4638 D0654 |
DSND 00001 00013 D0650 M000 |
END |
变频器设置:CD160=1
8N1 ASCII
波特率:9600 |
文章版权归西部工控xbgk所有,未经许可不得转载。
上一篇:PLC在矿井主排水控制系统的应用